Open Access
Issue |
MATEC Web Conf.
Volume 361, 2022
Concrete Solutions 2022 – 8th International Conference on Concrete Repair, Durability & Technology
|
|
---|---|---|
Article Number | 02003 | |
Number of page(s) | 5 | |
Section | Theme 2 - Electrochemical Repairs | |
DOI | https://doi.org/10.1051/matecconf/202236102003 | |
Published online | 30 June 2022 |
- A.M. Hassanein, G.K. Glass, N.R. Buenfeld, “Protection current distribution in reinforced concrete cathodic protection systems”, Cement & Concrete Composites 24, 159–167 (2002) [CrossRef] [Google Scholar]
- L. Bertolini et al, “Cathodic protection of new and old reinforced concrete structures”, Corrosion Science 35, 1633–1639 (1993) [Google Scholar]
- E. Redaelli, F. Lollini, L. Bertolini, Throwing power of localised anodes for the cathodic protection of slender carbonated concrete elements in atmospheric conditions, Construction and Building Materials. 39, 95–104 (2013) [CrossRef] [Google Scholar]
- J. Xu, W. Yao, “Current distribution in reinforced concrete cathodic protection system with conductive mortar overlay anode”, Construction and Building Materials 23, 2220–2226 (2009) [CrossRef] [Google Scholar]
- S. Bhuiyan et al, The effects of anode distance and corrosion activity on current distribution for ICCP systems, MATEC Web of Conferences - Concrete Solutions, 289, Article 03001 (2019) [Google Scholar]
- A.A. Sagüés, S.C. Kranc, “On the determination of polarisation diagrams of reinforcing steel in concrete”, Corrosion Science 48(8), 624–33 (1992) [CrossRef] [Google Scholar]
- G.K. Glass, A.M. Hassanein, “Surprisingly Effective Cathodic Protection”, Journal of Corrosion Science and Engineering 4, paper7 (2006) [Google Scholar]
- B.V. Belleghem, M. Maes, T. Soetens, Throwing power and service life of galvanic cathodic protection with embedded discrete anodes for steel reinforcement in chloride contaminated concrete, Construction and Building Materials, 310, (2021) [Google Scholar]
- U. Angst, M. Büchler, On the applicability of the Stern–Geary relationship to determine instantaneous corrosion rates in macro-cell corrosion. Materials and Corrosion, 66, 1017–1028, (2015) [CrossRef] [Google Scholar]
- M.S. Cheung, C. Cao, Application of cathodic protection for controlling macrocell corrosion in chloride contaminated RC structures, Construction and Building Materials, 45, 199–207 (2013) [CrossRef] [Google Scholar]
- C. Andrade, C. Alonso, Corrosion rate monitoring in the laboratory and on-site, Construction and Building Materials, 10(5), 315–328 (1996) [CrossRef] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.