Issue |
MATEC Web Conf.
Volume 218, 2018
The 1st International Conference on Industrial, Electrical and Electronics (ICIEE 2018)
|
|
---|---|---|
Article Number | 01008 | |
Number of page(s) | 9 | |
Section | Power System | |
DOI | https://doi.org/10.1051/matecconf/201821801008 | |
Published online | 26 October 2018 |
Leak Current Monitoring System On The Ground Cables Medium Voltage Transformer 150/20 kV
1
Electrical Engineering Program of ISTN, Jl. Moh. Kafli II Jagakarsa, Jakarta Selatan,
2
PT. PLN Transmisi Jawa Bag.Barat, APP Cawang Technician Substation System Jatirangon
*
Corresponding author: asofwan8@gmail.com
On January, 2017 there had been fault trip at PMT 150/20 kV transformer in Jatirangon substation. For fault detection, that rele differential phase T and REF 20 kV have worked to detect this fault. The resulted impact of this fault is Power outage in feeder a 1350 A, 35 MW and 5 Mvar. The cause of this fault is the occurrence of breakdown on ground cables 20kV T-phase-core 1. This results in a short circuit to the ground so that the differential protection relay and REF 20kV work because the relay detects a fault in the ptotection zone. The result of this research is the design of an early detection monitoring tool. This tool is used to determine the amount of leakage current on the ground cable in order to minimize the occurrence of interference that causes the occurrence of electrical power outage. The result of the leakage current monitor on the ground phase cable T obtained a current of 0.6A with temperature 35 °C. With thermal failure calculation method for leakage current obtained result of 0,56180A with temperature 35 °C. Comparison of the calculation with the measurement of leakage current on the ground cable T phase is obtained at 6.36%.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.