Open Access
Issue
MATEC Web of Conferences
Volume 46, 2016
2nd International Seminar for Fire Safety of Facades
Article Number 01004
Number of page(s) 9
Section Standardization and Regulation
DOI https://doi.org/10.1051/matecconf/20164601004
Published online 04 May 2016
  1. Jensen, G., “Fire spread modes and performance of fire stops in vented façade constructions – overview and standardization of test methods”, MATEC Web of Conferences, 9, 02002, 1st International Seminar for Fire Safety of Facades. Paris, France, November 14–15, 2013 [Google Scholar]
  2. prEN 1364-6, Fire resistance tests for non-loadbearing elements – Part 6: Cavity Barriers [Google Scholar]
  3. EN 1363-1:1999, Fire resistance tests. General requirements [Google Scholar]
  4. Smolka, Miroslav et al, “Semi-natural test methods to evaluate fire safety of wall claddings”. MATEC Web of Conferences, 9, 02002, 1st International Seminar for Fire Safety of Facades, Paris, France, November 14–15, 2013 [Google Scholar]
  5. ASTM E2912-13 Standard Test Method for Fire Test of Non-Mechanical Fire Dampers Used in Vented Construction [Google Scholar]
  6. ASTM E119. Standard Test Methods for Fire Tests of Building Construction and Materials [Google Scholar]
  7. Test report NBL A10109 dated 2010-10-21 from SINTEF NBL. Ad hoc test of fire resistance during the open state of exposure to fire [Google Scholar]
  8. ASTM E2886. Standard Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingement [Google Scholar]
  9. 2010 California Building Code, Title 24, Part 2 (First Printing), Includes Errata/Supplement through July 1, 2012. Chapter 7A – Materials and Construction Methods for Exterior Wildfire Exposure, Section 706A Vents [Google Scholar]
  10. NFPA 1144: Standard for Reducing Structure Ignition Hazards from Wildland Fire [Google Scholar]
  11. Östman, B. et al, “Brandsäkra trähus. Version 3” p. 125-130. AB Stjärntryck, 2012 [Google Scholar]
  12. EN 1366-4:2006+A1:2010, Fire Resistance Tests for Service Installations. Linear Joint Seals [Google Scholar]
  13. Test report 103011.11 dated 2009-03-27 from SINTEF NBL as according to NS-EN 1366-4:2006 [Google Scholar]
  14. LEPIR II. Test method for fire spread, 1970 [Google Scholar]
  15. SP FIRE 105 Issue 5. Large scale testing of façade systems. SP Boras, Sweden, 1994 [Google Scholar]
  16. BS 8414-1 Fire performance of external cladding systems. Test methods for non-loadbearing external cladding systems applied to the face of building. BSI, 2002 [Google Scholar]
  17. DIN E 4102-20 Brand verhalten von Baustoffen und Buteilen, Teil 20: Besonderer Nachweis für das Brandverhalten von Aussenwandbekleidungen. DIN 2009 [Google Scholar]
  18. Colwell, S. and Baker, T. “Fire exposure to external thermal insulation for walls of multistory buildings. Third edition” p. 5–6 and 14–15, BRE Trust, Garston, Watford, 2013 [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.