The Effect of Shear Wall Configuration on Seismic Performance in the Hotel Building
Department of Civil Engineering, Universitas Kristen Maranatha, 40164 Bandung, Indonesia
* Corresponding author: daud.rw@eng.maranatha.edu; hwiesiong1@gmail.com
Earthquake effects on the buildings must be evaluated within the current standard provision. The shape of building gives a unique seismic performance on the structure. In typical hotel building, the lobby area in the first floor usually has some slender columns due to the needs of higher clearance to give a widely space area. The slender columns in the big hall tends to create asymmetric building and torsional behaviour on seismic performance. This behaviour is one of the most frequent source of structural damage and failure. One of the solution is to add shear wall in elevator area. The purpose of this paper is to seek the effect of shear wall configuration in elevator area on the seismic performance through numerical analysis. There are some requirements for structural analysis under seismic load, such as: time period, modal analysis, story drift, and other details. In building with dual system, story shear in frame at each level must carry over 25 % of total story shear at that level. In this study, an eleven-storey hotel building located in Tanjung Pinang City, Indonesia was evaluated due to gravity and seismic load. For the building, the requirements of the time period from the standard are 1.21 sec (minimum) and 1.70 sec (maximum). As results, two-sided shear wall in X direction and two-sided shear wall in Y direction is recommended because it has the best seismic performance, time period below the minimum, story drift below allowable, the dynamic lateral load has meet minimum requirement (85% Static Load), and frame structure has carry more than 25% lateral load in dual system building.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.