  1. Chow, C.L., Chow, W.K., Han, S.S., and So, A.K.W. “Vertical air temperature profiles in a single skin glass façade with a ‘jumping fire' scenario”, Journal of Applied Fire Science, 17(2), 107–130, 2007–2008, [CrossRef] [Google Scholar]
  2. LPC. “Fire Spread in Multi-Storey Buildings with Glazed Curtain Wall Facades”, Loss Prevention Council, Borehamwood, England, 1999 [Google Scholar]
  3. Xie, Q., Zhang, H., Wan, Y., Zhang, Q., and Cheng, X., “Full-Scale Experimental Study on Crack and Fallout of Toughened Glass with Different Thicknesses”, Fire and Materials, 32, 293–306, 2008 [CrossRef] [Google Scholar]
  4. Yokoi, S., “Study on the Prevention of Fire Spread Caused by Hot Upward Current”, Report 34, Report of the Building Research Institute, Japan, 1960 [Google Scholar]
  5. Lee, Y.P., Delichatsios, M.A., and Silcock, G.W.H., “Heat fuxes and flame heights in facades from fires in enclosures of varying geometry”, Proc. Combust. Inst., 31, 2521–2528, 2007 [Google Scholar]
  6. Tang, F., Hu, L.H., Delichatsios, M.A, Lu, K.H., and Zhu W., “Experimental study on flame height and temperature profile of buoyant window spill plume from an under-ventilated compartment fire”, Int. J. Heat Mass Transfer, 55, 93–101, 2012 [CrossRef] [Google Scholar]
  7. Oleszkiewicz, I., “Vertical separation of windows using spandrel walls and horizontal projections”, Fire Technology, 27, 334–340, 1991 [CrossRef] [Google Scholar]
  8. Klopovic, S. and Turan, Ö.F., “Flames venting externally during full-scale flashover fires: two sample ventilation cases”, Fire Safety Journal, 31, 117–142, 1998 [CrossRef] [Google Scholar]
  9. Xie, Q., Zhang, H., Wan, Y., Zhang, Q., and Cheng, X. “Full-Scale Experimental Study on Crack and Fallout of Toughened Glass with Different Thicknesses”, Fire and Materials, 32, 293–306, 2008 [CrossRef] [Google Scholar]
  10. Ni, Z., Lu S., and Peng, L., “Experimental study on fire performance of double-skin glass facades”, Journal of Fire Sciences, 30, 457–472, 2012 [CrossRef] [Google Scholar]
  11. Babrauskas V., “Glass breakage in fires”, Issaquah, WA: FireScience and Technology Inc., 2010 [Google Scholar]
  12. BS 8414-1, “Fire performance of external cladding systems - Part 1: Test method for non-loadbearing external cladding systems applied to the face of the building”, 2002 [Google Scholar]
  13. McCaffrey, B.J., and Heskestad, G., “A robust bidirectional low - velocity probe for flame and fire application”, Combustion and Flame, 26, 125, 1976 [CrossRef] [Google Scholar]