Issue |
MATEC Web Conf.
Volume 364, 2022
International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR 2022)
|
|
---|---|---|
Article Number | 04014 | |
Number of page(s) | 6 | |
Section | Concrete Repair, Rehabilitation and Retrofitting - Concrete Patch Repairs and Bonded Overlays | |
DOI | https://doi.org/10.1051/matecconf/202236404014 | |
Published online | 30 September 2022 |
UHPC overlay as sustainable solution to preserve old concrete structures
Materials, Department of Civil, Environmental and Natural Resources Engineering, Luleå University of Technology, 97187 Luleå, Sweden
* Corresponding author: ankit.kothari@ltu.se
Concrete structures exposed to harsh environments, especially including bridges, harbor structures are often suffered from durability problems. Typical external signs include surface deterioration, cracking caused by for example sulphate attack, frost action or reinforcement corrosion. All are strongly linked to the porous microstructure of the binder matrix and chemical decomposition of certain phases. Full replacement of deteriorated concrete structures is costly and can be troublesome for their users. The increasing demand to reduce the carbon footprint and to prolong the service life of concrete structures adds yet another argument to restore the existing structures. One alternative is to use very dense Ultra-High-Performance concrete (UHPC) as an external protective coating. The goal of this study was to determine the interfacial bonding characteristics between a damaged normal concrete (NC) and the applied thin layer of the UHPC. To curb the CO2 emission, UHPC is produced by substituting 50 wt% of Portland cement with a fine limestone powder. Fresh and hardened properties, shrinkage and frost durability have been evaluated. Mechanical properties were determined on a full-scale hybrid element using ultrasonic pulse velocity (UPV) and bond test (pull-off test). The results showed a significant increase of mechanical properties. Despite the applied thin layer of UHPC and volumetric restrain from the substrate normal concrete (NC) only limited surface shrinkage cracks were observed. The bond test and UPV showed good excellent values.
Key words: Ultra-high-performance concrete (UHPC) / Normal concrete (NC) / Shrinkage / Frost durability / Ultrasonic pulse velocity (UPV) / Bond test (pull-off)
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.