The paper presents different models used to determine pressure losses in two-phase flows: the homogeneous model, the Lockhart-Martinelli, the Friedel and the Chisholm phase-slip models and the Martinelli-Nelson graphical method. The pressure losses are calculated for the evaporator of an OP-210 boiler with the output of 210×103 kg/h operating in one of the Polish power plants. The results obtained by means of the presented models are compared to each other.
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.