Simulation of water turbine integrated with electrical generator
Cracow University of Technology, Warszawska St. 24, 31-155 Cracow, Poland
* Corresponding author: dborkowski@pk.edu.pl
The paper presents the analysis of the small hydropower plant working at variable speed. The hydro-set that consists of the guide vanes and propeller turbine integrated with the permanent magnet synchronous generator is simulated by using Computational Fluid Dynamics (CFD) in Ansys Fluent v18.0. The k-ε and k-ω SST models, as well as the one-equation Spalart-Allmaras (SA) model, were tested. The comparison showed the significant divergence of the calculation results. The turbulence model selection influences the average value of the power and also the speed for which the power is maximal.
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.