Issue |
MATEC Web Conf.
Volume 232, 2018
2018 2nd International Conference on Electronic Information Technology and Computer Engineering (EITCE 2018)
|
|
---|---|---|
Article Number | 02016 | |
Number of page(s) | 5 | |
Section | 3D Images Reconstruction and Virtual System | |
DOI | https://doi.org/10.1051/matecconf/201823202016 | |
Published online | 19 November 2018 |
A Large Range Linear Displacement Calibration System Based on Coordinate Measurement and Laser Interference
1
Shanghai Institute of Measurement and Testing Technology, Shanghai, China
2
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200072, China
* Corresponding author: aZhihua Jiang: jiangzh@simt.com.cn
The linear displacement sensor is widely used in industrial measurement. The linear displacement sensor with measuring range less than 200mm is usually measured on a universal length measuring instrument. There is no good method to calibrate linear displacement sensor with measuring range larger than 200mm. The calibration system of linear displacement based on coordinate measurement and dual frequency laser interference is developed. The guide rail and measuring positioning system of coordinate measuring machine is used. The sampling signal of dual frequency laser interferometer is connected with the pulse signal triggered by coordinate measuring machine. The accurate position information of the linear displacement sensor is obtained and processed by industrial computer. According to JJF 1305-2011 Calibration Specification for Linear Displacement Sensor, a large range of linear displacement sensors is calibrated. The accuracy and reliability of linear displacement calibration system based on coordinate measurement and laser interference is verified.
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.