Influence of Iron Core on Critical Current and Inductance of an HTS Double Pancake Coil
1
Sino-Korean School of Multimedia Design, Shanghai University of Engineering Science, Shanghai, China
2
General Department of Power Grid Engineering Branch, China Energy Engineering Group Anhui Electric Power Design Institute Company Ltd., Hefei, China
3
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
4
Dali Power Supply Bureau Repair Institute, Dali City, Yunnan, China
a Corresponding author: seven840523@163.com
In a high temperature superconducting (HTS) DC induction heater, an HTS coil and an iron core are essential to generate DC magnetic field and form the magnetic circuit. To understand effect of the iron core on the critical current and the inductance of the HTS coil, we prepared a double pancake coil (DPC) and an iron core in this study, and measured the critical current and inductance of the DPC. The experimental results were compared with the numerically calculated ones as well. The measured critical currents of the DPC without and with the iron core are 89 A and 84 A, respectively. Thus, the iron core does affect the critical current. Moreover, the measured inductances are 6.94 mH and 45 mH. The measured data of the critical currents and the inductances are in good agreement with the calculated results
Key words: Comsol / HTS coil / Inductance / Ic / Magnetic field
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.