Issue |
MATEC Web Conf.
Volume 144, 2018
International Conference on Research in Mechanical Engineering Sciences (RiMES 2017)
|
|
---|---|---|
Article Number | 04019 | |
Number of page(s) | 8 | |
Section | Thermal Sciences | |
DOI | https://doi.org/10.1051/matecconf/201814404019 | |
Published online | 09 January 2018 |
Combined Natural Convection and Surface Radiation Inside Vented Triangular Enclosure - An Experimental Study
1
Department of Mechanical and Manufacturing Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal – 576104, Karnataka, India
2
Department of Mechanical Engineering, B.N.M. Institute of Technology, Banashankari, Bengaluru - 560 070, Karnataka, India
* Corresponding author: rahulraj2894@gmail.com
In the present experimental study, the influence of Opening ratio on the chamber temperature in case of vented triangular enclosure with hot base plate has been undertaken. Due to more flow passage, the average air temperature in the enclosure decreases by 12% for OR of 0.25 and 13% for OR of 0.5 compared to OR of 0.125. Similar trend is observed for Rayleigh number with a rise of 73% in OR 0.5 compared to OR of 0.125. Further, the influence of radiation heat transfer in the natural convection based enclosure is also studied. This kind of investigation is useful in the design and analysis of electronic cooling systems.
Key words: Natural Convection / Triangular Enclosure / Opening Ratio / Radiation heat transfer
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.