Issue |
MATEC Web Conf.
Volume 103, 2017
International Symposium on Civil and Environmental Engineering 2016 (ISCEE 2016)
|
|
---|---|---|
Article Number | 09010 | |
Number of page(s) | 11 | |
Section | Transportation Infrastructures and Highway Engineering | |
DOI | https://doi.org/10.1051/matecconf/201710309010 | |
Published online | 05 April 2017 |
The Effect of Deck Width Addition Toward Stability of Cable Stayed Bridge: Case Study of Siak Sri Indrapura Bridge, Riau
1 Civil Engineering and Environment Department, Universitas Gadjah Mada, Yogyakarta
2 Technology University of Yogyakarta
3 Department of Civil and Environmental Engineering, Universitas Gadjah Mada, Yogyakarta
* Corresponding author: bbsupri@tsipil.ugm.ac.id
An aeroelastic interaction always take places in long-span bridge, i.e. the dynamic relationship between wind forces (aerodynamic) and bridge structural motion (dynamics). Wind forces may lead to serviceability and safety problems, and may even cause instability of the whole bridge structure due to the flexibility nature of long span bridge structures.The slimer girder plate will make the structure more unstable as can be seen from the occurrence of lateral deformation. This paper presents the results analysis of cable stayed bridge that has total span of 640 m, two planes configuration of harp-typed hanger cable, the A shape pylons span along 320 m (main span),and side span of 160m. Structural analysis was conducted to determine the optimum ratio between width and spans of cable stayed bridge. The bridge was modeled with various width of 7 to 22 m. Structural modelling was conducted using SAP2000 software to analyze the structural stability of cable stayed bridge under wind load at speed of 35 m/s.The influence of wind loads to the cable stayed bridge stability can be seen based on the bridge deck deformation at the Y-axis (U2), in which for the width of the bridge deck of 7 m, 8 m, 9 m and 10 m, the deformation of U2 are 0.26 m; 0.17 m; 0.12 m and 0.10 m, respectively. Meanwhile, for bridge’s width of 11-22 m, the value of U2 axis deformation is relatively constant between 0.08 m to 0.07 m. This finding suggests that the ratio between width and length of bridge greatly affect the stability of the cable stayed bridge. Cable-stayed bridge, especially for concrete bridge, with two plain system having optimum ratio of width and length show no sign of an aerodynamic instability when fulfills the requirements of B ≥ L / 3.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.