Issue |
MATEC Web of Conferences
Volume 58, 2016
The 3rd Bali International Seminar on Science & Technology (BISSTECH 2015)
|
|
---|---|---|
Article Number | 01027 | |
Number of page(s) | 6 | |
Section | Chemical Engineering & Food Technology | |
DOI | https://doi.org/10.1051/matecconf/20165801027 | |
Published online | 23 May 2016 |
The Influence of Vibration on CaCO3 Scale Formation in Piping System
a Vocational Program in Mechanical Engineering, Diponegoro University
b Department of Chemical Engineering, UNTAG University in Semarang, Semarang Indonesia
c Graduate Program in Mechanical Engineering, Diponegoro University, Semarang Indonesia
E-mail : rhombo_hedral@yahoo.co.id
Carbonate scale is a common problem found in a piping system of industrial process. The presence of mechanical equipment such as turbine, compressor, blower, mixer and extruder produce a mechanical vibration on the piping system which is placed near these equipments. The influence of vibration on the CaCO3 scale formation in the piping system was experimentally investigated in the present study. The aim of the research was to understand the effect of vibration on the kinetics, deposition rates and the crystals formation in the synthetic solution. The solution was prepared using CaCl2 and Na2CO3 for concentration of calcium of 3.500 ppm, while the induction time, deposition rate, crystal growth were investigated at temperature of 25°C. In generating the vibration force, the mechanical equipment consisting of electrical motor, crankshaft, connecting rod and a vibration table were employed, including four coupons inside the pipe for investigating the scale formed. Frequency of the vibration was set at 0.00, 1.00 Hz and 2.00 Hz, respectively. A dosing pump with two inlets and two outlets was used to circulate the solutions at flowrate of 30 ml/min from each vessel to the coupons. After running for three hours, the induction time was recorded at 17; 10 and 8 minute with vibration frequency of 0.00; 1.00 and 2.00 Hz, respectively. The scale formed was then characterized using SEM/EDX for crystal morphology and elemental analysis. The results show that the deposition rates were 0.9457 and 3.3441 gram/h for the frequency of 1.00 and 2.00 Hz. The carbonate crystals found in coupon and filter were vaterite.
Key words: Carbonate scale / mechanical vibration / crystals / vaterite / aragonite / calcite
© Owned by the authors, published by EDP Sciences, 2016
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.