Open Access
Issue |
MATEC Web Conf.
Volume 410, 2025
2025 3rd International Conference on Materials Engineering, New Energy and Chemistry (MENEC 2025)
|
|
---|---|---|
Article Number | 04016 | |
Number of page(s) | 6 | |
Section | Intelligent Systems and Sensor Technologies for Autonomous Operations | |
DOI | https://doi.org/10.1051/matecconf/202541004016 | |
Published online | 24 July 2025 |
- Y. Xiang, Y. Lu, Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets. Nat. Chem. 3(9), 697–703 (2011) [Google Scholar]
- J. S. Swensen, Y. Xiao, B. S. Ferguson, A. A. Lubin, R. Y. Lai, A. J. Heeger, H. T. Soh, Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor. J. Am. Chem. Soc. 131(12), 4262–4266 (2009) [Google Scholar]
- M. N. Stojanovic, P. De Prada, D. W. Landry, Aptamer-based folding fluorescent sensor for cocaine. J. Am. Chem. Soc. 123(21), 4928–4931 (2001) [Google Scholar]
- V. Vallon, B. Muhlbauer, H. Osswald, Adenosine and kidney function. Physiol. Rev. 86(3), 901–940 (2006) [Google Scholar]
- D. E. Huizenga, J. W. Szostak, A DNA aptamer that binds adenosine and ATP. Biochemistry 34(2), 656–665 (1995) [CrossRef] [Google Scholar]
- S. Zhang, Y. Luan, M. Xiong, J. Zhang, R. Lake, Y. Lu, DNAzyme amplified aptasensing platform for ochratoxin A detection using a personal glucose meter. ACS Appl. Mater. Interfaces 13(8), 9472–9481 (2021) [Google Scholar]
- S. D. Stoev, Food security and foodborne mycotoxicoses, risk assessment, preventive measures, and underestimated hazard of masked mycotoxins or joint mycotoxin interaction. Food Toxicol. 9, 169–199 (2016) [Google Scholar]
- N. Ünüsan, Systematic review of mycotoxins in food and feeds in Turkey. Food Control 97, 1–14 (2019) [Google Scholar]
- X. Zhu, W. Li, L. Lin, X. Huang, H. Xu, G. Yang, Z. Lin, Target-responsive ratiometric fluorescent aptasensor for OTA based on energy transfer between [Ru(bpy)₃]²⁺ and silica quantum dots. Microchim. Acta 187, 1–8 (2020) [Google Scholar]
- Z. Li, N. Uno, X. Ding, L. Avery, D. Banach, C. Liu, Bioinspired CRISPR-mediated cascade reaction biosensor for molecular detection of HIV using a glucose meter. ACS Nano 17(4), 3966–3975 (2023) [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.