  1. EN 14630. Products and systems for the protection and repair of concrete structures - Test methods - Determination of carbonation depth in hardened concrete by the phenolphthalein method (2007) [Google Scholar]
  2. C. G. Petersen, Rapid chloride test, the RCT- method – Measurements of the chloride content of concrete, in situ, Dansk Beton 1, 22-27 (1991) [Google Scholar]
  3. EN ISO 12696. Cathodic protection of steel in concrete (2022) [Google Scholar]
  4. R. Polder, C. Andrade, B. Elsener, O. Vennesland, J. Gulikers, R. Weidert, M. Raupach, Test methods for onsite measurement of resistivity of concrete, RILEM TC 154-EMC: Electrochemical techniques for measuring metallic corrosion, Mater. Struct. 33, 603-611 (2000) https://doi.org/10.1007/BF02480599 [Google Scholar]
  5. L. Bertolini, B. Elsener, P. Pedeferri, E. Redaelli, R. Polder, Corrosion of steel in concrete: Prevention, daignosis, repair (John Wiley & Sons, 2013) https://doi.org/10.1002/9783527651696 [CrossRef] [Google Scholar]
  6. J. Broomfield, A historical review of impressed current cathodic protection of steel in concrete, Constr. Mater. 1, 1-21 (2021) https://doi.org/10.3390/constrmater1010001 [Google Scholar]
  7. ASTM C876 - 91, Standard test method for half- cell potentials of uncoated reinforcing steel in concrete (1999) [Google Scholar]
  8. CROW-CUR-Aanbeveling 130. Specialistische instandhoudingstechnieken – Kathodische bescherming van staal in beton (2024) [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.