  1. M. Nurbanasari. Investigation of leakage on water wall tube in a 660 MW supercritical boiler[J]. Journal of Failure Analysis & Prevention, 2014, 14(5): 657-661. [CrossRef] [Google Scholar]
  2. X.C. Song, X.J.Wu, Y.H. Kang. The method and apparatus of magnetic nondestructive testing for boiler waterwall tube[J]. Key Engineering Materials,2004, 270-273: 642-646. [CrossRef] [Google Scholar]
  3. L.B. Chen. An analysis and investigation on the leakage in water-wall tube of profiled flue of the coalburning boiler[J]. Journal of Shandong University (Engineering Science), 2005, 35(2): 14-17. [Google Scholar]
  4. F. Ren, J. Xu, J. Si. Failure analysis of a water wall tube[C]. Journal of Physics Conference Series, 2020, 1635: 012072. [CrossRef] [Google Scholar]
  5. P. Sun, C.C. Zhao, N. Wu et al. Water Wall Tube Leakage of 600 MW Power Plant Boiler[J]. Foundry Technology, 2017, 38(11): 2664-2666. [Google Scholar]
  6. Y.T.Y an, L.B. Niu, Y.X. Long, et al. Leakage cause analysis on water wall tube of a supercritical 600 MW.e.unit boiler[J]. PTCA (PARTA: PHYS.TEST.), 2019, 55(11): 779-803. [Google Scholar]
  7. National Technical Committee for Steel Standardization. Carbon and low-alloy steel determination of multi-element contents-spark discharge atomic emission spectrometric method (routine method): GB/T 4336-2016[S]. Beijing: China Standards Press, 2016. [Google Scholar]
  8. National Technical Committee for Steel Standardization. Seamless steel tubes and pipes for high pressure boiler: GB/T 5310-2017[S]. Beijing: China Standards Press, 2017. [Google Scholar]
  9. Technical Committee for metal material standards of power station in power industry. Power plant metallographic inspection and assessment guideline: DL/T 884-2019[S]. Beijing: China Electric Power Press, 2019. [Google Scholar]
  10. Y.B. He, W.J. Wang, C.M. Li, et al. Causes and prevention of high temperatures sulfur corrosion of water wall tubes of supercritical concurrent boiler[J]. Electric Power Construction, 2010, 31(10): 61-66. [Google Scholar]
  11. Z. Yin, H. Cai, Z.T. Hou, et al. Study on typical transverse crack of water wall tube of 1000 MW domestic ultra-supercritical units[J]. Journal of Science and Engineering, 2015, 33(03): 442-447. [Google Scholar]
  12. H. Xu, X.H. Xiong, X. Liu, et al. Study on high temperature corrosion products composition of water wall tube in a utility boiler and assessment of reconstruction[J]. Clean Coal Technology, 2019, 25(02): 144-148. [Google Scholar]