Open Access
Issue |
MATEC Web Conf.
Volume 267, 2019
2018 2nd AASRI International Conference on Intelligent Systems and Control (ISC 2018)
|
|
---|---|---|
Article Number | 01003 | |
Number of page(s) | 4 | |
Section | Control and Automation | |
DOI | https://doi.org/10.1051/matecconf/201926701003 | |
Published online | 11 February 2019 |
- Leondes CT, Mendel JM. Artiflcial intelligent control. Technical Report 4336, McDonnell-Douglas Astronautics Corporation, USA, 1967. [Google Scholar]
- Fu KS. Learning control systems and intelligent control systems: an intersection of artiflcial intelligence and automatic control. IEEE Transactions on Automatic Control, 1971, 16(1): 70–72. [CrossRef] [Google Scholar]
- Mayo CW, Bickford RG, Faulconer AJr. Electroencephalographically controlled anesthesia in abdominal surgery. J Am Med Assoc, 1950, 144: 1081-3. [CrossRef] [Google Scholar]
- Absalom AR, Glen JI, Zwart GJ. Target-Controlled Infusion: A Mature Technology. Anesth Analg. 2016; 122(1): 70-78. [CrossRef] [Google Scholar]
- Hu C, Horstman DJ, Shafer SL. Variability of target-controlled infusion is less than the variability after bolus injection. Anesthesiology. 2005, 102: 639-45. [CrossRef] [Google Scholar]
- Struys M, de Smet T. Principles of drug actions: target-controlled infusions and closed-loop administration. In: Evers AS, Maze M, Kharasch ED, eds. Anesthetic Pharmacology: Basic principles and Clinical Practice. Cambridge, UK: Cambridge University Press, 2011:103–122 [CrossRef] [Google Scholar]
- Struys MM, De Smet T, Glen JI. The History of Target-Controlled Infusion. Anesth. Analg. 2016; 122(1): 56-68. [CrossRef] [Google Scholar]
- C Yang, N Chen. Advances in Target Controlled Infusion for Anesthesia. Chinese Medical Equipment Journal. 2012; 33(2): 89-91 [Google Scholar]
- Kenny GN, Mantzaridis H. Closed-loop control of propofol anaesthesia. Br J Anaesth. 1999, 2: 223-228. [CrossRef] [Google Scholar]
- Biswas I, Mathew PJ, Singh RS. Evaluation of closed-loop anesthesia delivery for propofol anesthesia in pediatric cardiac surgery. Paediatr Anaesth. 2013, 23: 1145-1152. [Google Scholar]
- Hemmerling TM, Arbeid E, Wehbe M. Evaluation of a novel closed-loop total intravenous anaesthesia drug delivery system: a randomized controlled trial. Br J Anaesth. 2013, 110: 1031-1039. [CrossRef] [Google Scholar]
- Liu N, Le Guen M, Benabbes-Lambert F, et al. Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor. Anesthesiology. 2012, 116: 286-95. [CrossRef] [Google Scholar]
- J Guo, GS Yang, XD Xue. Application of narcotrend-guided propofol closed-loop target-controlled infusion in the gastrointestinal tumor operation. Chinese Journal of New Drugs. 2018, 27(5): 540-548. [Google Scholar]
- Coetzee JF, Glen JB, Wium CA, Boshoff L. Pharmacokinetic model selection for target controlled infusions of propofol: assessment of three parameter sets. Anesthesiology. 1995; 82: 1328e45. [CrossRef] [Google Scholar]
- Dussaussoy C, Peres M, Jaoul V. Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study. J Clin Monit Comput. 2014, 28: 35-40. [CrossRef] [Google Scholar]
- Liu Y, Li M, Yang D, Zhang X, Wu A, Yao S. Closed-Loop Control Better than OpenLoop Control of Profofol TCI Guided by BIS: A Randomized, Controlled, Multicenter Clinical Trial to Evaluate the CONCERT-CL Closed-Loop System. Plos One. 2015; 10(4): e0123862. [CrossRef] [Google Scholar]
- Lee AKY, Kong AYH, Kong CF. Performance of TCI Propofol Using the Schnider Model for Cardiac Surgery on Cardiopulmonary Bypass-A Pilot Study. J Cardiothorac Vasc Anesth 2018; 32 (2): 723-30. [CrossRef] [Google Scholar]
- Hegde HV, Puri GD, Kumar B, Behera A. Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma. J Clin Monit Comput. 2009, 23: 189-96. [CrossRef] [Google Scholar]
- DONG Liang, ZHANG Xing-an, XIONG Dong-sheng. The Design of Anaesthesia Depth Intelligent Control System Based on TCI. Chinese Journal of Medical Physics. 2013; 30(2): 4052-6. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.