Open Access
Issue
MATEC Web Conf.
Volume 199, 2018
International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR 2018)
Article Number 01004
Number of page(s) 11
Section Keynote Papers
DOI https://doi.org/10.1051/matecconf/201819901004
Published online 31 October 2018
  1. M. Di Prisco, G. Plizzari, L. Vandewalle, Fibre reinforced concrete: new design perspectives, Materials and Structures, 42 (9), 1261–1281 (2009). [Google Scholar]
  2. A. Reggia, F. Macobatti, F. Minelli, G. A. Plizzari, S. Sgobba, Proceedings of the 4th International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR-4, 2015) [Google Scholar]
  3. Fédération Internationale du Béton, fib Model Code for Concrete Structures 2010, Final Complete Draft, fib bulletins 65 and 66 (2012). [Google Scholar]
  4. Tomaževič, M., Weiss, P., Velechovsky, T., The influence of rigidity of floors on the seismic behavior of old stone-masonry building, European Earthquake Engineering, 3, 28–41 (1991). [Google Scholar]
  5. Magenes, G., Calvi, G.M., Kingsley, G.R., 1995. Experimental and numerical investigation on a brick masonry building prototype numerical prediction of the experiment. University of Pavia, Italy. [Google Scholar]
  6. Benedetti, D., Carydis, P., Pezzoli, P., Shaking table test on 24 masonry buildings, Earthquake Engineering & Structural Dynamics, 27, 67–90 (1998). [CrossRef] [Google Scholar]
  7. Dolce, M., Ponzo, F. C., Goretti, A., Moroni, C., Nigro, D., Giordano, F., De Canio, G., Marnetto, R., 3D dynamic tests on 2/3 scale masonry buildings upgraded with different systems, Proceedings of 14th World Conference on Earthquake Engineering, Beijing, China (2008). [Google Scholar]
  8. Mazzon, N., Chavez, C. M., Valluzzi, M. R., Casarin, F., Modena, C., Shaking table test on multi-leaf stone masonry structures: Analysis of stiffness decay, Advanced Materials Research, 133, 647–652 (2010). [CrossRef] [Google Scholar]
  9. Magenes, G., Penna, A., Galasco, A., A full-scale shaking table test on a two-storey stone masonry building, 14th European Conference on Earthquake Engineer., Paper n.1432. Ohrid, Macedonia (2010). [Google Scholar]
  10. Magenes, G., Penna, A., Senaldi, I. E., Rota, M., Galasco, A., Shaking table test of a strengthened full-scale stone masonry building with flexible diaphragms, Int. Jour. of Arch. Heritage: Conserv., Analysis, and Restor., 8(3), 349–375 (2014). [Google Scholar]
  11. Italian Ministry of Infrastructures and Transportations, Decree 14 gennaio 2008, Norme tecniche per le costruzioni (2008). [Google Scholar]
  12. Facconi, F., Conforti, A., Minelli, F., Plizzari, G. A., Improving shear strength of unreinforced masonry walls by nano-reinforced fibrous mortar coating, Materials and structures, 48(8), 2557–2574 (2014). [CrossRef] [Google Scholar]
  13. Diana 10.1. User’s manual. TNO DIANA BV, Delft, The Netherlands; 2016. [Google Scholar]
  14. CEN, EN 1992-1-1: Eurocode 2. Design of concrete structures. Part 1-1: General rules and rules for buildings, (2005). [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.