Comparison of Thermal Sensations Under the Same Conditions in the Climatic Chamber and the Lecture Hall
Kielce Uuniversity of Technology, al. Tysiaclecia P.P.7, 25-314 Kielce, Poland
* Corresponding author: ldebska@tu.kielce.pl
For many people, the feeling of thermal comfort becomes an important aspect of helping to increase concentration at work or study. Creating an appropriate indoor microclimate becomes a huge challenge for many designers of modern construction. The most important assumption of the work is to compare the thermal sensations of a group of four, aged 23 to 30, staying in the lecture class of an intelligent building and in a climatic chamber with the same internal parameters. For this purpose, the Testo 400 environmental meter was used, collecting the necessary parameters from the environment, and specially created surveys describing people's thermal feelings during the study. The air temperature and relative humidity were as follows: 21.7 °C and 30.80 %, while for the climatic chamber the same data was applied, but at the end of the study both parameters increased to 21.9 °C and 40.50 %. Moreover, it turned out that people in the lecture hall felt worse than in the climatic chamber with similar internal values. In addition, the average Thermal Sensation Vote (TSV) response showed that the perceived environment is comfortable for the study group staying in the climatic chamber, as opposed to the feeling of influenza in the room. Unfortunately, the Predicted Mean Vote (PMV) for the room and chamber exceeded the set value described in the ISO 7730 standard.
Key words: thermal comfort / Fanger model / microclimate
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.