Structural health monitoring and structural modifications of industrial building subjected to dynamic loading
Technical university of Košice, Faculty of Civil Engineering, 042 00 Košice, Slovak Republic
* Corresponding author: robert.soltys@tuke.sk
A complex structural, static and dynamic review of an existing steel ceiling has been realised after two years of service and the completion of subsequent construction work. The construction work involved the reconstruction of a steel structure and structural modifications to the ceiling, which is part of the production hall. The construction work was realised in order to reduce the vibration response of the ceiling. The interior of the steel structure was supplemented by steel structural elements to share the load transfer of automatic washing machines. The structural behaviour of the ceiling was monitored before and after the modification. Accelerations of the ceiling were time-domain-monitored at specific locations. Measured data was transformed to the spectral-domain which is represented by power spectral densities.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.