Research on Performance Test Characteristics of Solar Energy ORC Generator Set
1
Dongguan Guanneng Green Energy Service Co., Ltd. Dongguan 523000, China
2
Guangdong Electric Power Research Institute Energy technologies Ltd. Guangzhou 510080, China
3
Guangdong Power Grid Co., Ltd. Dongguan Power Supply Bureau, Dongguan 523000, China
In order to study the performance of low-temperature solar-powered ORC generator sets, a solar-powered ORC power generation test bench was designed and built. In the experiment, R-123 was used as the organic Rankine cycle working fluid, and the solar ORC power generation system was experimentally studied. The research results show that when the direct solar radiation intensity is about 400W, the temperature of the heat transfer oil at the outlet of the collector can reach 140 °C. When the temperature of the heat transfer oil at the outlet of the collector is around 110°C, the collector efficiency of the collector can reach about 60%. Under the heat source condition, when the power cycle part is switched from the basic cycle to the regenerative cycle mode, the collector heat collection efficiency can reach about 60%. Under the heat source condition, when the power cycle part is switched from the basic cycle mode to the regenerative cycle mode, the measured efficiency is increased from 9.3% to 10.8%, and the measured cycle efficiency is increased from 1.57% to 1.67%, which is an increase of 6.07%. The measured cycle system efficiency is about 10%, and the heat recovery mode is slightly higher than the basic cycle mode. The organic Rankine cycle performance under different working fluid flows was also investigated in the experiment. The maximum measured average power was 386.27 W when the working fluid flow was 6.88 kg·s. At a certain heat source temperature, as the flow rate of the working fluid increases, the inlet pressure of the expander increases, and the circulating output work also increases. Under a certain working fluid flow rate, as the temperature of the heat source increases, the temperature of the inlet of the expander increases, and the inlet pressure increases. the cycle output work also increased.
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.