Issue |
MATEC Web Conf.
Volume 196, 2018
XXVII R-S-P Seminar, Theoretical Foundation of Civil Engineering (27RSP) (TFoCE 2018)
|
|
---|---|---|
Article Number | 02011 | |
Number of page(s) | 6 | |
Section | Building Structures | |
DOI | https://doi.org/10.1051/matecconf/201819602011 | |
Published online | 03 September 2018 |
Pipe-concrete columns of buildings and their fire-resistance determination
Samara State Technical University, Academy of Architecture and Civil Engineering,
Molodogvardeyskaya St., 194,
Samara,
443001,
Russia
*
Corresponding author: kafvv@mail.ru
The research recognizes the necessity of developing a new method of calculation of pipe-concrete columns fire-resistance. It is important for expending the area of their application in construction of buildings and structures; in unique structures as well. The authors apply a simplified mathematical description of the process of pipe-concrete columns resistance to the standard fire effect. This method helps to increase the accuracy of fire resistance level determination to expand these constructions use. If buildings materials are rationally combined, it is possible to produce reliable and sufficiently fireproof structures. Pipe-concrete columns which are, in fact, metal pipes filled with concrete can serve as an example of such structures. Nowadays, field tests are used to determine pipe-concrete constructions fire resistance. The authors introduce a methodology of theoretical determination of pipe-concrete columns fire resistance limit. The use of the proposed methodology makes it possible to reduce labor and economic costs while determining buildings resistance with the use of the pipe-concrete. It opens a possibility of pipe-concrete structures reasonable application in construction practice. The use of this new method allows us to determine pipe-concrete columns fire resistance without resorting to natural fire. It also increases the accuracy of statistical quality control and non-destructive tests. The calculations made in this study as well as previous tests conducted by other researches prove that there is no need for additional fire protection of pipe-concrete columns.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.