Experimental study of temperatures in characteristic sections of the working zone of a closed two-phase thermosyphon under the condition of a heat removal by external periphery
National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
* Corresponding author: nurpeiis_atlant@mail.ru
We present the results of the experimental study of temperature fields in a closed two-phase thermosyphon. Operational modes of a thermosyphon with different heat supply conditions are studied experimentally using setup consisting of the copper case, systems of heat supply and removal in evaporation and condensation zones, and temperature recording facilities. The height of the heat exchanger is 161 mm, thickness of the side walls and bottom wall are 1.5 mm and 2 mm, respectively, inner diameter is 39 mm. Heat is supplied to the bottom wall by heating element. The heat carrier is distilled water. We obtained thermograms when heat fluxes to the bottom wall of the thermosyphon are 695 – 2136 W/m2.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.