Buoyancy-Driven Ventilation Generated by the Double-Skin Façade of a High-Rise Building in Tropical Climate: Case Study Bandung, Indonesia
School of Architecture, Planning and Policy Development, Institut Teknologi Bandung, Jalan Ganesha 10, Bandung
* Corresponding author: akhlishda@gmail.com
High-rise buildings in tropical region is identical to the use of mechanical Air Conditioning in massive scale. Nevertheless, there is an encouragement to high-rise buildings to reduce its energy consumptions, since they consume quite large amount of energy. This challenge can be overcome with various of strategies, one of them, by means of reducing the cooling load of mechanical Air Conditioning in high-rise building. Prospects come from the modern tall building design strategies, for example the use of double-skin façade to give addition of building skin which could provide indoor temperature protection from outside. Double-skin façade system has continued to increase in buildings in a tropical region such as in Indonesia. However, there is another potential of double skin façade, which is the possibility to increase the buoyancy effect in the air gap between the skin and building envelope. The possibility needs to be studied in order to give a proper way in designing double-skin façade of a high-rise building, especially on Bandung-Indonesia tropical climate. This paper explores the potential of double-skin façade in driving the air inside the façade to generate natural ventilation for a high-rise building in Bandung climate condition. Two parameters are used in exploring the buoyancy force, the width of double-skin façade and the temperature of the skin façade. In general, double-skin façade of a high-rise building in tropical climate can generate buoyancy driven ventilation for the building, it relates strongly to the distance between of the double-skin façade and the building envelope.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.