Issue |
MATEC Web Conf.
Volume 135, 2017
8th International Conference on Mechanical and Manufacturing Engineering 2017 (ICME’17)
|
|
---|---|---|
Article Number | 00006 | |
Number of page(s) | 6 | |
DOI | https://doi.org/10.1051/matecconf/201713500006 | |
Published online | 20 November 2017 |
Numerical Study on Self-Cleaning Canister Filter With Add-On Filter Cap
1
Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia
2
Flow Analysis, Simulation, and Turbulence Research Group, Universiti Tun Hussein Onn Malaysia
1 Corresponding author: akmaln@uthm.edu.my.
Filtration in a turbo machinery system such as a gas turbine will ensure that the air entering the inlet is free from contaminants that could bring damage to the main system. Self-cleaning filter systems for gas turbines are designed for continuously efficient flow filtration. A good filter would be able to maintain its effectiveness over a longer time period, prolonging the duration between filter replacements and providing lower pressure drop over its operating lifetime. With this goal in mind, the current study is focused on the difference in pressure loss of the benchmark Salutary Avenue Self-cleaning filter in comparison to a new design with an add-on filter cap. Geometry for the add-on filter cap will be based from Salutary Avenue Manufacturing Sdn.Bhd. SOLIDWORKS software was used to model the geometry of the filter, while simulation analysis on the flow through the filter was done using Computational Fluid Dynamic (CFD) software. The simulations are based on a low velocity condition, in which the parameter for the inlet velocity are set at 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s respectively. From the simulation data obtained for the inlet velocities considered, the pressure drop reduction of the modified filter compared to the benchmark was found to be between 7.59% and 30.18%. All in all, the modification of the filter cap produced a lower pressure drop in comparison with the benchmark filter; an improvement of 27.02% for the total pressure drop was obtained.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (http://creativecommons.org/licenses/by/4.0/).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.