Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
Poltava National Technical Yuri Kondratyuk University, Department of Civil Engineering, Pershotravnevyi Avenue, 24, Poltava, 36011, Ukraine
* Corresponding author: galinska@i.ua
The results of theoretical studies of heat-shielding properties of the angle of external wall a residential building are presented. The brick wall thickness of 510 mm was considered. The studies were performed for the I-st temperature zone of Ukraine. Heat insulation was located on the external side of enclosure. Thermal protection problems of the angle are consideration of the impact of heat-conductive inclusion on adjusted heat transfer resistance of enclosure. Conductive inclusion on the external angle area is its configuration. An additional layer of insulation in the angle area is necessary to use for bringing the level of thermal protection of angle area to the standards. The results of calculations of two-dimensional temperature fields were used for the analysis of thermal protection. Two options for additional insulation were studied. The first option: continuous strip insulation covering the external wall angle. Another one provides division of additional insulation layer into two parts and displacement them from the angle within the design scheme. Studies were performed for different thickness of additional insulation. There was additionally taking into account the value of insulation displacement from the angle for the second option. The optimal location and size of additional insulation were determined. The minimum amount of additional insulation under which the thermal protection requirements are performed was accepted like optimality criterion.
© The Authors, published by EDP Sciences, 2017
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.