Cracks beyond the limits: Are they a problem in XS2?
1 RPCP, Gouda, The Netherlands
2 ETH, Zurich, Switzerland
* Corresponding author: robpolder@robpolder.demon.nl
The maximum design crack width under normal environmental conditions is given as 0.3 mm, supposed to prevent corrosion of reinforcement. We discuss the consequences when this limit is applied to permanently submerged reinforced concrete structures in sea water (XS2), taking into account that in permanently submerged concrete, there is insufficient oxygen to support significant corrosion. One case concerns permanently submerged harbour quay slabs. Calculated bending crack widths were above the limit of 0.3 mm and additional reinforcement was deemed needed. Assuming that oxygen transport was limited, the corrosion risk was considered negligible and adding reinforcement was not necessary. Another case concerns caissons in shallow sea water built by slipforming. The slipforming caused some “lifting” cracks above 0.3 mm surface width. In the submerged parts, oxygen diffusion through sea water inside the cracks is so slow that corrosion was insignificant over the required 100-year service life; costly injection was not needed. It should be noted that significant corrosion is possible if macro-cells can form, e.g. in hollow-leg structures where cathodic oxygen reduction on the aerated inside may support corrosion in cracks on the outside. Under those conditions high corrosion rates are possible; such cracks should be avoided or repaired.
© The Authors, published by EDP Sciences, 2025
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.