Issue |
MATEC Web Conf.
Volume 345, 2021
20th Conference on Power System Engineering
|
|
---|---|---|
Article Number | 00028 | |
Number of page(s) | 12 | |
DOI | https://doi.org/10.1051/matecconf/202134500028 | |
Published online | 12 October 2021 |
Operational and economic analysis of a Velox-type combined heat & power plant with a throttle valve
Silesian University of Technology, Department of Power Engineering and Turbomachinery, Konarskiego 18, 44-100 Gliwice, Poland
* Corresponding author: krystian.smolka@polsl.pl
For many years, the Department of Power Engineering and Turbomachinery of the Silesian University of Technology has been using a small-capacity (about 500 kWe) steam-gas power plant. Based on many years of experience in operation of this power plant utilizing the Velox-type gas-steam system, an idea arose to modify this type of thermal power cycle to create a combined heat and power (CHP) plant of small capacity, dedicated for distributed heat and power production or production process steam with high temperature. Previous thermodynamic and economic analysis of that type of low-power CHP plant confirmed many advantages of using this type of solution in low-power engineering. The new idea is to add a throttle valve between the economizer and the evaporator for the reference cycle of the gas-steam Velox-type CHP plant. It was further assumed that water would partially be vaporized on the valve. This paper presents a thermodynamic and economic analysis of this type of a system with an added throttle valve. Downstream the valve, the evaporated water fraction is fed directly into the steam superheater. It is determined how such a retrofit affects the system thermodynamic and economic characteristics. The system is modelled in the EBSILON® Professional 14 software.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.