One-way translational magnetic mass damper model for structural response control against dynamic loadings
1
Civil Engineering Technology Department, Faculty of Civil Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02100 Sg. Chuchuh, Padang Besar, Perlis, Malaysia
2
Engineering Seismology & Earthquake Engineering Reaserch (e-SEER), Institute of Noise & Vibration, Universiti Teknologi Malaysia, UTM, 81310 Skudai, Johor, malaysia.
3
Civil Engineering Programme, Faculty of Engineering, UMS, 88899 Kota Kinabalu, Sabah, Malaysia.
4
Department of Civil Engineering, School of Engineering & Technology, University College of Technology Sibu, 96000 Sibu, Sarawak, Malaysia.
* Corresponding author: nurulashikinbahaman@gmail.com
Structural responses should be reduced to minimize the consequent structural damage caused by dynamic excitation. The one-way translational magnetic mass damper model is developed as a new type of damper for the purpose of structural response control. The damper utilizes the concept of repulsive force between magnets with same poles to create a magnetic force to stabilize or bring the structure back to its original position. The dynamic performance of the structure was tested using a harmonic shaking table. In this study, the three parameters used are excitation speeds: 2.5V (low), 6.0V (medium) and 8.5V (high); strength of magnets: weak (N35), medium (N45) and strong (N52); and the mass in the damper: 40 g, 101 g and 162 g. The correlations of the parameters towards the structural displacement are verified in the testing. The displacement is highly reduced up to 100% at the first level and 85.2% at the fifth level. The most optimum structural response control was attained when a strong magnetic strength and mass of 162 g are used. When tested with three excitation speeds; 2.5V, 6.0V and 8.5V, the damper with this setting provides the optimum damping effect towards the structure in terms of displacement.
© The Authors, published by EDP Sciences, 2018
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.