A statistical comparison between calculated and experimentally evaluated crack spacing measures given in practise codes for the design of reinforced concrete elements made with self-healing concrete
1
RDC Research and Development Concrete, 46055 València, Spain
2
Universitat Politècnica de València, 46022 València, Spain
3
Eduardo Torroja Institute of Construction Science (IETcc-CSIC), 28033 Madrid, Spain
* Corresponding author: kirandabral@rdconcrete.com
Available design codes provide formulations to evaluate the maximum spacing between the cracks, which then is used to calculate the crack width in concrete structures. This paper discusses the parameters controlling the crack spacing and develops an experimental test program on a set of industrial-scale reinforced concrete elements cast with self-healing concretes to be tested under flexural actions. This study provides a wide picture of the limits of maximum, minimum, and average spacing occurring in the beams. A comparison is highlighted between the calculated and experimentally evaluated measures. It was observed that the provisions given in Eurocode 2 and Model code 2010 present a good approach for the calculation, always with a small degree of overestimation for concrete without fibres. On the other hand, the values calculated using recommendations from NFP 18-710, the overestimation is higher. The influence of loading levels seems to not affect the number of cracks with an increase in concrete cover. The experimentally evaluated ranges to relate maximum and minimum spacing with the average value in a loaded region are given. No influence of using self-healing agents was detected.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.