Issue |
MATEC Web Conf.
Volume 199, 2018
International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR 2018)
|
|
---|---|---|
Article Number | 07017 | |
Number of page(s) | 8 | |
Section | Repair Materials and Systems | |
DOI | https://doi.org/10.1051/matecconf/201819907017 | |
Published online | 31 October 2018 |
Alternative patch repair materials for rebar corrosion damage
Concrete research and structural integrity research unit (CoMSIRU), Department of Civil Engineering, University of Cape Town (UCT), South Africa.
* Corresponding author: primeshjassa@gmail.com
One of the most common methods adopted in the rehabilitation of corrosion-damaged concrete is the patch repair procedure. However, in practice this method has shown to often be unreliable as a consequence of the widespread occurrence of shrinkage induced cracking and poor substrate-patch adhesion leading to debonding of the patch repair. From a practical point of view, such failed repair systems essentially restore the repaired concrete back to a deteriorated state. There is a common belief that repairing concrete with specialised proprietary repair materials would guarantee durability. However, the widespread premature failure of patch repairs conducted using such materials has proven the contrary. This paper presents an understanding of the materials and issues concerning the durability and serviceability of concrete patch repairs, with the aim of identifying alternative non-structural patch repair materials for the effective repair of corrosion-damaged concrete structures. The potential patch repair materials researched were polymer-cement concrete (copolymer of vinyl acetate and ethylene with 5% cement replacement) and 60%, 80% and 100% fly ash (FA) mortar. Patch repairs were conducted on substrate moulds to test application and observe cracking/debonding occurrence. Furthermore, compressive strength, durability index, accelerated drying shrinkage, restrained shrinkage, workability and scanning electron microscopy (SEM) tests were conducted to determine the properties of the materials developed with reference to performance requirements of durable concrete repairs. It was concluded that the 60% FA and polymer-cement concrete repair materials had the best overall performance. This research established that innovative alternative repair materials such as a 60% FA or polymer-cement concrete material, can be developed for non-structural patch repairs with improved long-term performance relative to conventional materials.
© The Authors, published by EDP Sciences, 2018
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.