Root cause analysis of the folding deformation for the expansion joint in the nuclear power station
SuZhou Nuclear Power research Institute, ShenZhen, 518038, China
In the nuclear power station, the expansion joint of moisture separator re-heater (MSR for short) was founded locally folding deformation under the outage condition. Folding deformation increasing will lead expansion joint leak, it would cause emergency stop when leaking seriously. To solve these problems, this paper analysis mainly on three aspects: the material organization performance, the expansion joint installation and the stress characteristic of expansion joint. Both the verticality deviation in the process of installation and the material hardness value exceed standard are the root cause of these problems. At the end of the paper, the improvements have been put forward for this problem.
© The Authors, published by EDP Sciences, 2016
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.